Operation and Maintenance FAQ#

Deploy and Startup FAQ#

1. How to confirm that the cluster is running normally?#

Although there is one-click to start the script, due to the numerous configurations, problems such as “the port is occupied” and “the directory does not have read and write permissions” may occur. These problems can only be identified when the server process is running, and there is no timely feedback after exiting. (If monitoring is configured, it can be checked directly by monitoring.) Therefore, please make sure that all server processes in the cluster are running normally.

It can be queried by ps axu | grep openmldb. (Note that mon is used as the daemon process in the official run script, but the running of the mon process does not mean that the OpenMLDB server process is running.)

If the processes are all running and the cluster still behaves abnormally, you need to query the server log. You can give priority to ‘WARN’ and ‘ERROR’ level logs, which are most likely the root cause.

Server FAQ#

1. Why is there a warning of “Fail to write into Socket” in the log?#

http_rpc_protocol.cpp:911] Fail to write into Socket{id=xx fd=xx addr=xxx} (0x7a7ca00): Unknown error 1014 [1014]

This is the log that the server side will print. Generally, the client side uses the connection pool or short connection mode. After the RPC times out, the connection will be closed. When the server writes back the response, it finds that the connection has been closed and reports this error. Got EOF means that EOF has been received before (the peer has closed the connection normally). The client side uses the single connection mode and the server side generally does not report this.

2. The initial ttl setting of table data is not suitable, how to adjust it?#

This needs to be modified using nsclient, which cannot be done by ordinary clients. For nsclient startup method and command, see ns client

Use the command setttl in nsclient to change the ttl of a table, similar to

setttl table_name ttl_type ttl [ttl] [index_name]

As you can see, if you configure the name of the index at the end of the command, you can only modify the ttl of a single index.

Caution

Changes to setttl will not take effect in time and will be affected by the gc_interval configuration of the tablet server. (The configuration of each tablet server is independent and does not affect each other.)

For example, if the gc_interval of a tablet server is 1h, then the ttl configuration reload will be performed at the last moment of the next gc (in the worst case, it will be reloaded after 1h). This time the gc that reloads the ttl will not eliminate the data according to the latest ttl. The latest ttl will be used for data elimination during the next gc.

Therefore, after ttl is changed, it takes two gc intervals to take effect. please wait patiently.

Of course, you can adjust the gc_interval of the tablet server, but this configuration cannot be changed dynamically, it can only take effect after restarting. Therefore, if the memory pressure is high, you can try to expand the capacity and migrate the data shards to reduce the memory pressure. Adjusting gc_interval lightly is not recommended.

3. If a warning log appears: Last Join right table is empty, what does it mean?#

Generally speaking, this is a normal phenomenon and does not represent an anomaly in the cluster. It’s just that the right table of the join in the runner is empty, while is a possible phenomenon, and is instead likely to be a data problem.

Client FAQ#

1. Why am I getting a warning log for Reached timeout?#

rpc_client.h:xxx] request error. [E1008] Reached timeout=xxxms

This is because the timeout setting of the rpc request sent by the client itself is small, and the client itself disconnects itself. Note that this is a timeout for rpc.

It is divided into the following situations:

Synchronized offline job#

This happens easily when using synchronized offline commands. you can use

> SET @@job_timeout = "600000";

To adjust the timeout time of rpc, use ‘ms’ units.

normal request#

If it is a simple query or insert, there will be a timeout, and the general request_timeout configuration needs to be changed.

  1. CLI: cannot be changed at this time

  2. JAVA: SDK direct connection, adjust SdkOption.requestTimeout; JDBC, adjust the parameter requestTimeout in url

  3. Python: cannot be changed at this time

2. Why am I getting the warning log of Got EOF of Socket?#

rpc_client.h:xxx] request error. [E1014]Got EOF of Socket{id=x fd=x addr=xxx} (xx)

This is because the addr side actively disconnected, and the address of addr is most likely taskmanager. This does not mean that the taskmanager is abnormal, but that the taskmanager side thinks that the connection is inactive and has exceeded the keepAliveTime, and actively disconnects the communication channel. In version 0.5.0 and later, the taskmanager’s server.channel_keep_alive_time can be increased to increase the tolerance of inactive channels. The default value is 1800s (0.5h), especially when using synchronous offline commands, this value may need to be adjusted appropriately. In versions before 0.5.0, this configuration cannot be changed, please upgrade the taskmanager version.